Protection and automation of transf. RADIUS AVTOMATIKA Sirius UV, Sirius 3 LV 04, etc.
PROTECTION AND AUTOMATION OF TRANSFORMERS
Sirius T, Sirius T BPT is a microprocessor protection device designed to perform the functions of the main protection of a two-winding (including split winding) transformer with a higher voltage of 35-220 kV. It is also possible to use a reactor or a powerful synchronous motor as a differential protection. It contains a replacement MTZ VN and MTZ NN with an external combined voltage start.
Sirius T3 is a microprocessor protection device designed to perform the functions of the main protection of a three-winding (or two-winding with split winding) transformer or an autotransformer with a higher voltage of 35-220 kV. It is also possible to use a dual reactor, a powerful synchronous motor as a differential protection, or as a longitudinal differential protection of a busbar with three connections. It contains a replacement MTZ VN, MTZ CH, MTZ NN with an external combined voltage start.
Sirius 2 PH is a transformer voltage regulation device designed to control RPN electric drives with automatic adjustment of the transformation coefficient of power transformers. The device is intended for installation on panels and in cabinets in relay halls and control panels of power plants and substations of 3-500 kV.
Sirius UV is a microprocessor protection device designed to perform the functions of control, automation and signaling of a 35, 110 and 220 kV high-voltage switch with three-phase control, as well as to perform the functions of backup protections of a power transformer or replacement protections of an overhead line. It contains step-by-step protections of relative selectivity and automation functions.
Sirius UV BPT is a microprocessor protection device designed to perform the functions of control, automation and signaling of a 35, 110 and 220 kV high-voltage switch with three-phase control, as well as to perform the functions of backup protections of a power transformer or replacement protections of an air line. It contains step-by-step protections of relative selectivity and automation functions.
Sirius 3 UV is a microprocessor protection device designed to perform the functions of control, automation and signaling of a 110-220 kV high-voltage switch with three-phase control in networks with an effectively grounded neutral, as well as to perform the functions of backup protections of a power transformer or replacement protections of an overhead line. It contains step-by-step protections of relative selectivity and automation functions.
Sirius 3 DZO 02 is a microprocessor protection device designed to perform the functions of the main differential protection of a power transformer (autotransformer) and a busbar of voltage class 6-220 kV (including in cases of their connection to the system via two switches). The number of controlled three–phase groups of measuring TT is up to four.
Sirius 3 LV 04 is a microprocessor protection device designed to protect transformers and autotransformers with a voltage of up to 220 kV, as well as control, automation and signaling of a high-voltage switch with three-phase control (AUV, APV and URV). It contains a set of step-by-step protections (CSR) of relative selectivity.
Sirius AART is a microprocessor device for automatic emergency unloading of a transformer, designed to provide protection against overload of transformers by automatically disconnecting a number of load consumers depending on the current, taking into account the thermal model of the transformer.
All RADIUS AVTOMATIKA products
About RADIUS AVTOMATIKA
-
A WIDE RANGE OF
The company offers a wide range of equipment and an integrated approach to customer support. Provides pre-and after-sales support. -
quality
RADIUS AUTOMATION creates reliable relay protection and automation systems that meet the modern requirements of power supply networks. Each piece of equipment undergoes technical control of the OTC. -
CERTIFICATION
The company carries out current control of its products for compliance with the EMC requirements. The company's quality management system is certified for compliance with the requirements of GOST R ISO 9001-2011 (ISO 9001:2008).
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89